Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
1330For DG or Transformer body earthing, is it necessary to terminate the earth bus to earth pit directly? If not terminated to earth pit directly in earth pit and connected to any common bus strip which ultimately connects to earth pit, what will be the pros and cons?
1 1683If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.
1194We have two APFC panels in same station. I need how to connect CT in two APFC panels.can we take one CT in series connection or two separate CTs.
1231we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor
1196Post New Electrical Engineering Questions
how dose servo motor works
hi , i have 150 kw loud and we need 50 m cabil,i want to know wich size cabil we use. thanks
how we can calculate power factor in single phase & three phase ?thank u
What is the function of electron gun assembly used in crt?
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
concept of busbar and load dispatching..?
For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?
what is deffrence between squirral cage and wound rotor in IM?
When steam condenses and becomes water at the same temperature, the specific heat for the process in kJ/kg k is
what is circuit recombiner and how it is different from circuit breaker
Why hydropower stations are preferred solution for meeting peak loads in grids?
why co incidence factor considered in transformer sizing?
What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps
i have applied for the post of RRB section engineering chennai board please send me previou papers and solved answer. my mail id jagarapusrinivas@gmail.com
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?