Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Battery is a voltage source? give one example of current source and why?

Suzlon,

1295

Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1330

For DG or Transformer body earthing, is it necessary to terminate the earth bus to earth pit directly? If not terminated to earth pit directly in earth pit and connected to any common bus strip which ultimately connects to earth pit, what will be the pros and cons?

1 1683

If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.

1194

Electrical 'C' license full abbreviation , and full form

1618

kindly send me 11KV MV motor differential protection procedure by primary injection method.

1209

What happen if transformer neutral path get removed ?

1 1782

We have two APFC panels in same station. I need how to connect CT in two APFC panels.can we take one CT in series connection or two separate CTs.

1231

please explain to me how to calculate current,voltage,resistance with formula??

1187

for what voltage will reactive power be largest in 380 kv line : a) 375kv b)380kv c)385kv

1212

What are the raitings of Mcb,mccb and Acb in detail ??

Engineering Vision,

1338

What is icu and ics in Acb and how many time icu or ics passes from breaker?

Engineering Vision,

1272

why we use Test Terminal Block in 11 KV and 33 KV electrical panels.

EMC,

1157

before synchronizing an alternator,power factor is leading ,why?

CUMI,

1252

we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor

1196


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

how dose servo motor works

1682


hi , i have 150 kw loud and we need 50 m cabil,i want to know wich size cabil we use. thanks

1901


how we can calculate power factor in single phase & three phase ?thank u

1764


What is the function of electron gun assembly used in crt?

863


A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.

1090


concept of busbar and load dispatching..?

2118


For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?

1669


what is deffrence between squirral cage and wound rotor in IM?

1718


When steam condenses and becomes water at the same temperature, the specific heat for the process in kJ/kg k is

873


what is circuit recombiner and how it is different from circuit breaker

1572


Why hydropower stations are preferred solution for meeting peak loads in grids?

760


why co incidence factor considered in transformer sizing?

1611


What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps

1774


i have applied for the post of RRB section engineering chennai board please send me previou papers and solved answer. my mail id jagarapusrinivas@gmail.com

1723


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1442