Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what is the difference between earth, neutral and ground?

Farnek, Shyam Indus Power, Spiro Solutions,

1 3248

During the main stator winding insulation testing (phase to ground)of 11kv alternator (Lerysomer) i found 0 and resistance with multimeter and found 20 killo ohm while the power cables are connected both end (Generator & VCB). In VCB PT (Potential transformer) are connected. Please any body explain that method of insulation is correct or not? also describe of PT connections

Private,

1 2839

3.7 kw motor ,how much sq mm cabel want to bare this motor load

1 2906

What is PLL? what are it's advantages?

BREB,

1 2606

what will be the breaking capacity of MCCB of 1000kVA (6% Impedence) transformer? Voltage being 415V, Power Factor 0.8.

BPC,

2 2914

Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere

Kazi Farms, SKI Carbon Black,

1572

what are balanced and unbalanced loads

GGH,

1 2641

1. What are the types of Transformer?

Valdel,

1 2426

On what basis do you decide the ONAN (Oil Natural air natural) or Dry type transformer for a project?

Semac,

1558

Which are the types of breakers used in High Tension (HT) side?

1 3004

How to calculate the no of Ceiling fan (1200mm sweep) per unit area?

2008

No load tap changing transformer working

1603

can the measured percentage error during calibration of single phase energy meter be negative?

2363

I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?

1623

how a generating station can monitor its multi users power factor. What type of incentive /penalty is associated with power factor management.

Sojex,

1 2177


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

how can we select the appropriate VCB ?

2263


why do we lay up the core of a cable?

1982


What is the difference between a Root Locus plot and a Bode plot?

1233


1)What is a Triode? What are its uses? 2) What is a Triac? 3) What is a Thyristor?

2577


what is the id1 & id2 setting in differential protection relay of CSPC?

2759


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.

1952


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1912


how to calculate voltage drop and followed by cable calculation?is there avail in formula?

2012


what is Fault level? why it is calculated? how will u decide same for our plant?

2006


What will be the effect if I use inverter as UPS mood?

2160


What Is HO factor in power selection

2016


What do you mean by turns ratio of instrument transformer?

1053


what is the difference b/w ATS and HTS?

2141


Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?

1971


we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???

1951