During the main stator winding insulation testing (phase to ground)of 11kv alternator (Lerysomer) i found 0 and resistance with multimeter and found 20 killo ohm while the power cables are connected both end (Generator & VCB). In VCB PT (Potential transformer) are connected. Please any body explain that method of insulation is correct or not? also describe of PT connections
1 2916what will be the breaking capacity of MCCB of 1000kVA (6% Impedence) transformer? Voltage being 415V, Power Factor 0.8.
BPC,
2 3016On what basis do you decide the ONAN (Oil Natural air natural) or Dry type transformer for a project?
1606I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?
1660how a generating station can monitor its multi users power factor. What type of incentive /penalty is associated with power factor management.
1 2260Post New Electrical Engineering Questions
how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)
What is dielectric loss?
what is solkor relay and which condition it will act?
WHAT IS VCB SAFETY
why we used dc supply for field in dg set
does any one know where we can purchase insulation oil for high voltage oil filled cables
can i connect REF and Differencial relay in 1 CT core for transformer protection?
what is transient voltage?
is there any current and voltage drop on liquid resistance starter water/soda tank ?
Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC
How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?
100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.
what is the difference between changer, converter and transformer?
1) What are your personal strength? 2) What are your personal areas of improvement? 3) What are your expectations from from a particular job? 4) what are your carrier objectives?
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?