size of the traditional brick is 248*121*71 in mm,but why the size are like this.why the size are not like that 211*154*75 in mm
1 4950Current ctc and expected ctc? Should i tell or as per Compnany norms? I am not fresher (1 yr exp) so how should i Face it
1 3944How t find the quantity of materials required for construction of a wall of length 10x5x0.2
NCC,
2 7029how to reduce size of column 450 x 750 to 230 x.... if it is cut in area of bathroom? means it appears in bathroon any shifting or any other option....building is g + 10 and the bathroom is at first floor...
2373at the beam-column junction point tell me how much beam bars should pass through column ring ? 3 or 2 or 1 . answer with reason. if it is not happen then what will be he effect ?
1 5439Post New Civil Engineering Questions
20 mpa what is the quantity of cement sand and aggregate in one cubic meter of pcc non rainforcement concreate kindly answer including formaula thanks
why development length = 50D . why not 100D
the distrubution system in water supplies is designed on the basis of avg daily demand peak hourly demand coincident of draft greater of B & C
How can you distinguish between sorption, absorption and adsorption?
Wat is meant by Aecron brick?
A rock anchor 3 1/2” in diameter is placed in rock. The which has an allowable shear strength of 1200 psi. Determine the required anchorage length to safely carry a 80 ton load using a 2.0:1 F.S
what is difference between fluidity and workability also how palsticizer works
The building has 12 columns of 12x9 in 3 rows of 4 each in a plot of 50'x30', The central row is strengthened with 16mm twisted rods. The roof area is 1500 sft including balconies. calculate the load factor per sft. Also indicate the number of roofs the building can withstand.
How to build the floor to ceiling bookcase?
i am completed my b.tech EEE in 2009,,,iam trying the job 3+ for AUTO CAD (ELECTRICAL),, what is the market for autocad electrical in hyderabad... how to handle the intervws give some suggestions ?
How you can use different dimension tools in cad? What are the different dimensions available?
how can can column be corrected when the design is not safe ? is the increasing the clearcover a solution?
Formula for calculating the volume of bulb in underreamed pile
questions with answers to face an interview of an civil engineer regarding RCC buidings
if we know load bearing capacity of the soil and building load falling in each footing, then how to choose the type of foundation??? and if it is shallow foundation then which type of shallow foundation should be choosen i.e either strip or isolated or raft or combined or cantilever footing???????