Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

SIR MAY I KNOW IF RADAR TYPE LEVEL TRANSMITTER SHOWING IN THE FIELD 0 % LEVEL AND IN DCS SHOWING 100% THEN WHAT IS THE CAUSE I CLEAN THE CHAMBER & TAKEN ONLINE BUT ONLY ONCE ITS BECOME ZERO IN DCS BUT AGAIN 100% SHOWING IN DCS,THEN I REMOVE THE POWER SUPLLY AND CONNECT IT AGAIN .IS IT OK BUT STILL IN THE DCS ITS 100% AND ON THE DISPLAY ITS INITILAZIATION PLEASE HELP ME READRING THIS?

4 7515

draw the block diagram of a level transmitter ?

Hira Group, Samsung,

2394

while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?

Gasco,

2209

why we are using perforted cable tray for control cable and ladder tray for power cable

1 9201

What FLOW METER generally used in Gas plant?

Gasco,

5 10450

What do you do as a Engineering person EPC for Sizing&Selecting Control Valve?

1 2830

what is the reset offset and control system in instrumentation

ABB,

3612

How to O2 analyzer works?

1 5960

how to work static pressure sensore how to work dpt

1873

if we open the inlet of an air regulator ,how it will affect the out put of regulator? (out put of regulator is using to operate an on-off valve.it is an air to open valve,and valve is in open position.my doubt is air regulator will hold the valve in open or not,if there is no consumption or leak in regulator out put side ,we only loose the input pressure.)

Asian Paints,

4 7266

what is meaning of static pressure

Ambuja,

4 8330

What is difference between loop and zone ?

Adgas, Bilt,

5 13997

What is the Difference between PE,IE and ISE

2 23190

Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

Yokogawa,

2280

what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

4016


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure

1916


How the warning lamp of a charging-system is activated ?

2638


What are different types of orifice plates? State their uses.

1149


why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .

2883


what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail

2307


We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.

2328


What is the basic difference between Modbus and CAN Open Protocols

6442


What is difference between radial vibration and axial vibration explain in detail .

1720


what is 24vdc live and dry supply

2269


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1663


what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?

3021


Describe a time when you anticipated potential problems and developed preventive measures.

2914


how many types of viberation transmitter and how to calibrate and where use of vibration transmitter

2138


Displace type LT to be calibrated in workshop, wt. 40, dia- 60 mm, density- 0.8kg/cm3.

1846


How to Calibrate Coriolis Flow transmitter in field

1266