Hi, I am Gurunathan. I am in need of ONGC, IOCL, DRDO
technical test ( chemical engineering)and general aptitude
questions. If anyone has kindly post it to me soon.
No Answer is Posted For this Question
Be the First to Post Answer
Question 49 - According to rules of thumb in chemical process design, consider the use of an expander for reducing the pressure of a gas when more than 20 horsepowers can be recovered. The theoretical adiabatic horsepower (THp) for expanding a gas could be estimated from the equation : THp = Q [ Ti / (8130a) ] [ 1 - (Po / Pi) ^ a ] where 3 ^ 3 is 3 power 3 or 27, Q is volumetric flowrate in standard cubic feet per minute, Ti is inlet temperature in degree Rankine, a = (k - 1) / k where k = Cp / Cv, Po and Pi are reference and systemic pressures respectively. (a) Assume Cp / Cv = 1.4, Po = 14.7 psia, (temperature in degree Rankine) = [ (temperature in degree Celsius) + 273.15 ] (9 / 5), nitrogen gas at Pi = 90 psia and 25 degree Celsius flowing at Q = 230 standard cubic feet per minute is to be vented to the atmosphere. According to rules of thumb, should an expander or a valve be used? (b) Find the outlet temperature To by using the equation To = Ti (Po / Pi) ^ a.
Who built the first production scale pla (polylactic acid) facility?
Which type of drier is used for drying wet material?
What are the chemicals are required for cooling tower passivation? Please mail me in my Email id:-nsput2000@gmail.com
CHEMICAL ENERGY BALANCE - EXAMPLE 11.1 : Please match the term A - E with the stated definition i - v. Terms : A. Yield. B. Selectivity. C. Relative saturation. D. Molal saturation. E. Absolute saturation. Definitions : i. (moles of desired product formed) / (moles that would have been formed if there were no side reactions and the limiting reactant has reacted completely); ii. (moles of desired product formed) / (moles of undesired product formed); iii. (relative humidity 40 % means partial pressure of water vapour equals 4 / 10 of the vapour pressure of water at the system temperature); iv. (moles of vapour) / (moles of vapour dry gas); v. (mass of vapour) / (mass of dry gas).
What is the working of vaccum distilation coloumn in a petroleum refinary?
Question 51 - A batch reactor is designed for the system of the irreversible, elementary liquid-phase hydration of butylene oxide that produces butylene glycol. At the reaction temperature T = 323 K, the reaction rate constant is k = 0.00083 L / (mol - min). The initial concentration of butylene oxide is 0.25 mol / L = Ca. The reaction is conducted using water as the solvent, so that water is in large excess. (a) Let the molecular weight of water is 18 g / mol and the mass of 1 kg in 1 L of water, calculate the molar density of water, Cb in the unit of mol / L. (b) Determine the final conversion, X of butylene oxide in the batch reactor after t = 45 min of reaction time. Use the formula X = 1 - 1 / exp [ kt (Cb) ] derived from material balance. (c) Find the equation of t as a function of X.
Two methanol-water mixtures are contained in separate tanks. The first mixture contains 40.0 wt % methanol and the second contains 70.0 wt % methanol. If 200 kg of the first mixture is combined with 150 kg of the second, what are the mass and composition of the product? The symbol of weight percent is wt %.
Why should chemical equation be balanced?
Explain what type of pump may be appropriate for a liquid near saturation, a low flow rate, and very limited npsha (net positive suction head available)?
hi, i have completed B.tech Chemical enggneering, plz can anyone provide me GVK BIO company's interview questions. iam attending the interview for the first time..
Question 88 - In the calculation of the growth of bacteria, colony forming unit (CFU) in serial dilution is used. In a laboratory, viable count assay is used to estimate CFU. Formula applied is CFU / mL = (number of colonies x dilution) / (amount plated, in unit mL). Acceptable plate count is either between 20 and 200 or between 30 and 300 according to 2 different references. A wastewater sample of 200 ml is added to and mixed with 1.8 L of sterile water. Another 200 ml of the mixture is added to and mixed with 1.8 L of sterile water. (a) Calculate the dilution of first mixture and the dilution of the second mixture. (b) 100 microlitres of wastewater samples from the first mixture and the second mixture are placed separately on 2 different alga plates. The first plate has 250 colonies and the second plate has 23 colonies. Calculate the average CFU / mL.