Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
Answer / kang chuen tat (malaysia - pen
Answer 13 : In the same state, total heat changes in heating = total heat changes in cooling for acetone. H = N ( total heat of sensible + heat of vaporization) = 100 (mol / s) [ (30.2) + (4.06 + 3.82) ] (kJ / mol) = 3808 kJ / s. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
Explain the factors involved in considering the choice of dry screw compressor?
Question 57 – There are 2 simultaneous equations : (A1) x + (B1) y = D1 and (A2) x + (B2) y = D2. (a) By using Excel program, find the values of x and y when A1 = 80, A2 = 150, B1 = 52, B2 = 100, D1 = 3.5 and D2 = 2.3. (b) Write the expression of Excel in the form of =MMULT(MINVERSE(W:X),Y:Z) in order to get the values of x and y. W, X, Y and Z may be A1, A2, B1, B2, D1 and D2.
Explain what types of valves are recommended for slurry services?
ENGINEERING DRAWING - EXAMPLE 18.2 : For a Vernier scale that consists of 0.11 cm per section, estimate the length on actual standard ruler of 0.1 cm per section for 2.39 m and 0.91 m.
UNIT OPERATION - EXAMPLE 9.2 : A distillation column separates 10000 kg / hr of a mixture containing equal mass of benzene and toluene. The product D recovered from the condenser at the top of the column contains 95 % benzene, and the bottom W from the column contains 96 % toluene. The vapor V entering the condenser from the top of the column is 8000 kg / hr. A portion of the product from the condenser is returned to the column as reflux R, and the rest is withdrawn as the final product D. Assume that V, R, and D are identical in composition since V is condensed completely. Find the ratio of the amount refluxed R to the product withdrawn D. Hint : Solve the simultaneous equations as follow in order to find the answer (R / D) : 10000 = D + W; 10000 (0.5) = D (0.95) + W (0.04); 8000 = R + D.
What are the steps taken to operate a tank-blanketing valve?
What kind of concerns is associated with temperature pinch points in condensers?
Define wet bulb globe temperature?
R sir, i need placement paper of last years of IOCL in chemical sream...... send me the question paper as soon as possible on my email address.
18 Answers ABC, IOCL, ONGC,
What is the symbol of sodium?
what is difference between urea and NPK fertiliser?
The water is superheated steam at 440 degree Celsius and 17.32 megapascals. Estimate the enthalpy of the steam above. From the steam table for water at 440 degree Celsius, enthalpy of steam, h at 18 megapascals is 3103.7 kilojoules per kilogram and at 16 megapascal is 3062.8 kilojoules per kilogram. Assume that h = mP c where P is pressure; m and c are constants at fixed temperature with small differences in P.
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)