we have one pumping station and 4.6 MW 7 no.s synchronous motors.so there is no required HT capacitor to improve power factor.But we have two no.s of 25 Mva power transformer connect to distribute the power for motors connect with 220 kv line.So i have required the HT capacitor to improve power factor at HT side i mean power transformer bus side.So please suggest how much HT capacitor banks required for same.
how to identyfy cable sizes?
can we use engine degreaser for electrical motors?
As we know,charged clouds(from which lightning stroke initiates)may be charged with either +ve charge or -ve charge. Now say one cluster of cloude is fully charged with +ve charge & another cluster is fully charged with -ve charge. In the sky these two cluster of charged clouds have come in such a distance that, if they come clouser by some few yeards then the lightning discharge will take place between these two cluster of clouds. Under such a situation an Aircraft came inbetween. what happend??
what u meant of power plant?
How to calculate the size of window A.C. for 200 Sq. ft room?
what is the technical term when and alternator's prime mover fails.
Mention the difference between Analogue and Digital circuit?
what is quality factor in series resonance circuit and calculate the factor of voltage magnification? how it happens?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is the difference between series and shunt compensation using facts in a transmission line
8 Answers College School Exams Tests, Genco,
What are the components connected in between the power supply coming from an electric pole to HT & LT Panels in a large commercial building or how the power supply connected from Electric pole to Transformer & then to the HT & LT panels of a building? Please send me answers via mail, my id is yogiagarwal@gmail.com. If possible, please give a line diagram.
How to decide no. of Step and Kvar for APFC Panel 40 kvar MD: 33.12 KVA Avg pf : 0.8540