Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why urasil use in hplc column perfomance?



why urasil use in hplc column perfomance?..

Answer / palanisamy

In reverse phase chromatography Uracil compound more
ratanied in mobile phase,it will elute first so we are
calculating capacity factor taking void volume for this
uracil peak

Is This Answer Correct ?    4 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

why we are using 6 dosage units in dissolution, and why we are using 6 tablets in disintegation test.is there any scientific reason beyond 6?

1 Answers   ABC, Alembic, IPCA,


What should be the calibration procedure for wavelength accuracy in case of HPLC?

4 Answers  


In specificity what parametrs are consider why that parametrs

2 Answers  


What is the diff b/n OVI and Residual solvents

1 Answers  


What is difference btw UV detector & RID detector

4 Answers  


why should we calibrate pH meter with 4,9.2 and 7.4 buffers particularly?

5 Answers   Celon Labs,


what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

0 Answers  


From peak purity spectrum, where or at which point peak purity angle & purity threshold is checked?

1 Answers   Cipla, MSN Pharma,


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

0 Answers  


Why we use Uracil for HPLC calibration in Detector wave ength accuracy test?

5 Answers  


What is differences between the Instrument and Equipment

2 Answers   Aurobindo,


In lcms analysis some times we get sodium and potassium adducts. if the compound is havine sodium ions how can we confirm wether sodium is from sample or it is a adduct?

2 Answers   Teva Pharmaceuticals,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)