Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why reference flow required during hplc analysis on rid?



why reference flow required during hplc analysis on rid?..

Answer / stephie

Because mobile phase has refraction index itself, therefore we need to subtract this proportion to minimize the error.

Is This Answer Correct ?    4 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

Dear Sir, This is Thirunavukkarasu am working in Ordain Health Care AR&D, Am Having one problem While doing method development my question Metadoxine and Pyridoxine same chemical nature and structural activity i tried lot of methods but Analyte eluted same Retantion time i cant separate both peaks. solubility, pH both are same only only difference melting point metadoxine 210 C Pyridoxine 102 C please do the help needful for me

5 Answers   Ordain Solutions,


why 0.1M OR 1M Perchloric acid standardisation done after 24 hours?

1 Answers   Cipla,


what is peak purity ??

10 Answers   Cipla, Zyg Pharma,


Why water not directed by FID detector 

2 Answers   Amoli Organics, Lupin,


why we wre doing linearity siudiec in hplc method validation

3 Answers   Cipla,


What is rs test why we are performing rs test?

0 Answers  


what is diffrence between Specific optical rotation, optical rotation?

3 Answers  


What is void volume & dead volueme

3 Answers   Bayer, Lupin,


gc Calibration % RSD failed what is the possible reasons?

5 Answers   Divis Laboratories,


why potassium dicromate use in calibration of UV VIIBLE SPECTROCOPY ?

3 Answers  


Which parameters require to do in tech transfer?

0 Answers  


What is difference b/t uv detector and rid

5 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)