what the effect will occur if we increase the airgap in induction motor..

Answer / hemalatha

due to increase of air gap stator current gets increased in
turn which causes decrease of power factor..

Is This Answer Correct ?    38 Yes 2 No

what the effect will occur if we increase the airgap in induction motor..

Answer / manishsingh

air gap high = leakage flux high = mutual flux low = X high = pf low = torque low

generally we put .5mm airgap in IM

Is This Answer Correct ?    19 Yes 2 No

what the effect will occur if we increase the airgap in induction motor..

Answer / kapil bhatt

SINCE THE TORQUE DEVELOPED IN THE MOTOR DEPENDS ON THE AIR
GAP ALSO, INCREASING THE GAP WILL GIVE US A LESSER TORQUE
BECAUSE THE MAGNETIC FIELDS OF STATOR AND ROTOR WILL NOT
STRONGLY CLUTCH TOGETHER THEREBY GIVING US A LESSER SPEED.

Is This Answer Correct ?    8 Yes 4 No

Post New Answer

More Electrical Engineering Interview Questions

in 5 mva transformer 33/11 kv s/s what rating of capacitor bank is required & what is the fourmula for rating

6 Answers  


Does Lightening arrest requires Earthing?..

5 Answers  


what is sinwave ups

1 Answers   Exide,


define transformer

1 Answers  


what is the application of dynamic Breaking resistor in inverter ? & How it works ?

2 Answers  






Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.

0 Answers   Engineers India Limited,


what is entropy?

3 Answers   NTPC,


Mr. mohh sahid m not satisfied for ur answer to the que weather the size of transformer increases or decreases withchange in fr for more detail go to the answer given by me

0 Answers   Sail,


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

0 Answers  


11 kv input, 66 kv input advantages

0 Answers  


what is breaking capacity

1 Answers  


what r the types of detectors? state the location these detectors?

3 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)