Can u explain : how capacitor act when the supply is given
is a.c and d.c.
I know that when d.c supply is given then the capacitor
charges and becomes open circuited.
But please say about when a.c is given.
I have seen that when a.c supply is given ,it charges and
discharges,
But when we plug in capacitor to our daily supply and take
it out ,then we join those wires spark will appear,which
seems charge is present ,but when a.c is given it should
charge and discharge
Answers were Sorted based on User's Feedback
Answer / k.prakashchandra
The capacitor is in discharged condition at beginning and
charged to maximum at the peak voltage, of each positive and
negative half cycle.The charge remaining in the capacitor
depends on the point of disconnection of supply.
| Is This Answer Correct ? | 4 Yes | 2 No |
The supply was removed when the capacitor was in charged
condition i.e. before complete discharge took place
| Is This Answer Correct ? | 2 Yes | 2 No |
Answer / shashwat
Your Question contains d answer itself, what exactly u want 2 knw???
| Is This Answer Correct ? | 2 Yes | 3 No |
What is step signal?
what is CRGO Transformers?
6 Answers MSETCL Maharashtra State Electricity Transmission Co Ltd, TATA,
What are the advantages and disadvantes of delta and star connections in transformers and alternators?
what is function of rtu?
What is the exact formula for one weber of magnetic flux?
The coils having selfinductancs 10mh and15mh,effective inductance 40mh when connected in series aiding. what will be the equivalent inductance if we connect them in series opposing?
If DG runing time Neutral earth connection Dissconect what will be the effect in load and equipments.
In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?
in short circuit. test of a transformer 5 to 10% ofvrated voltage is used why??? if we use rated voltafe then what will be?
what are all types of cross section in AC cables?
what is meant by negative half cycle
why voltage ratings of xmission are in 11, 33,66kv and why not 11.5 ,16,19 or any other
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)