Can u explain : how capacitor act when the supply is given
is a.c and d.c.
I know that when d.c supply is given then the capacitor
charges and becomes open circuited.
But please say about when a.c is given.
I have seen that when a.c supply is given ,it charges and
discharges,
But when we plug in capacitor to our daily supply and take
it out ,then we join those wires spark will appear,which
seems charge is present ,but when a.c is given it should
charge and discharge
Answer Posted / k.prakashchandra
The supply was removed when the capacitor was in charged
condition i.e. before complete discharge took place
Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
How two nos. 130 kw D.C motor get synchronise using D.C drive.
PLEASE SEND ME NTPC RELATED INFORMATION LIKE WHICH TOPICS HAV MORE SCOPE,BOOKS TO READ,CUT OFF...PLEASE.mail at thiru.1203@gmail.com
how to do the ductor test?
how to calculate cooling requirement of datacentre from electrical load?
How to measure size of cable on a given load
In motors how many types of cooling systems were used?
specify the inbuilt protections in DG
What is the main cause of magnetism?
If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)
What shall be the secondary output voltage if the primary winding of a 220/6V, 50 Hz transformer is energized by an 110V, 60 Hz supply?
what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv
Define thermal resistance in the context of power amplifier.
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
what is distribution board?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?