what is the difference between energy efficient and high efficiency motors..

Answer / rakesh

Energy Efficient motors are the type...which produces
expected o/p with almost less losses.but high efficiency
motors are those whose efficency is based on the rating of
the m/c.In some cases for a ideal motor both are equal..

Is This Answer Correct ?    8 Yes 3 No

what is the difference between energy efficient and high efficiency motors..

Answer / amit kar.

Energy Efficient Motors:An "Energy Efficient motors are the
motors which give the same output as standard motor using
lesser amount of power or energy.
High Efficiency Motors:Motor efficiency is the ratio of
mechanical power o/p to the electrical p/w i/p.

Is This Answer Correct ?    4 Yes 5 No

Post New Answer

More Electrical Engineering Interview Questions

If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.

0 Answers   Usha Capacitors,


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

0 Answers   AB, JLL,


Is there any scope for an electrical engineer in MRF company......

1 Answers  


how to calculate the ac and dc wire losses with calculations plz tell me

3 Answers   Apollo,


why making capacity is more than breaking capacity?

14 Answers   Essar, Indo Asian, Infinity,






Relative synchronous generator

1 Answers  


what will happen when ac is applied resistor,inductor,capcitor?

1 Answers  


Is any generator is developed which is operated with out diesal or other expensive source?

0 Answers  


what is the funda of earthing? Explain breifly about earthing?

5 Answers   IOCL,


What are the types of feedback oscillators?

0 Answers  


Why 11KV PT Secondaries [(11000/1.732)/(110/1.732)/ (110 / 3)]are in star connection ? And why the same should not be in delta ?

1 Answers  


if two heater of rating 1KW,200v are connected in series 100v supply what will be the power taken

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16637)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)