Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


calculations of LOD & LOQ

Answers were Sorted based on User's Feedback



calculations of LOD & LOQ..

Answer / murugesan

LOD : signal to noise ratio 3;1
LOQ : signal to noise ratio 10;1

Is This Answer Correct ?    25 Yes 3 No

calculations of LOD & LOQ..

Answer / supriya

LOD: Limit of detection -It should be between 3-10
(by S/N ratio method)

LOQ: Limit of Quantification -It should be between 10-30
(by S/N ratio method)

Is This Answer Correct ?    9 Yes 1 No

calculations of LOD & LOQ..

Answer / phanindra

LOD: signal to noise ratio 3Or2:1

LOQ : signal to noise ratio 10:1


According to ICH Q2B

Is This Answer Correct ?    5 Yes 1 No

calculations of LOD & LOQ..

Answer / omkar singh yadav

LOD is 3-10 by siganal to noise ratio.
LOQ is 10-30 by siganal to noise raito

LOD = 10*Standard deviation/ slope of calibration curve

LOQ = 3.3*standard devition/ slope of calibrtion curve

Standard devation is calculating in many ways.
in Simple Linerity curve it is also called Styrex.

For Japan market is calclted as Standard error and slope
is calculated as X-variable.

There are so many ways to calculate the LOQ and LOD

Is This Answer Correct ?    4 Yes 2 No

Post New Answer

More Pharmacy Interview Questions

In Dry powder inhalation Andersen casacde impacor for FPF performing in that we adjusting 60LPM/MIN and time 4second ,why? Explain

1 Answers   Dr Reddys, Reddy Labs,


What is column efficiency and performance ? And how can we know the column is better?

0 Answers   Shreegen Pharma,


what the procedure followed in pharmacokinetic study of drug in plasma

2 Answers  


any deviation can be changed into the change control?

4 Answers  


what should be minimum limit of working standard

1 Answers  


What is the difference between Calibration & Validation?

2 Answers  


what is relative response factor in related substance

2 Answers  


How LOD & LOQ calculating?

3 Answers   Dr Reddys,


what are the limit of LOD and LOQ

3 Answers   Cipla,


What are closely monitor parameters in stability study?

1 Answers   Reddy Labs,


what u know about ranbaxy company

1 Answers   Ranbaxy,


basic of hplc,columns used

1 Answers  


Categories