Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What are various power system instabilities and what are
their effects on power system operation?



What are various power system instabilities and what are their effects on power system operation?..

Answer / iamdon

There are mainly three types of power system instabilities

1)Rotor angle instability:It arises due to real power(P)
imbalance.If the situation continues for a long time there
will be mechanical problem with rotor.

2)voltage instability:It arises due to reactive power(Q)
imbalance.If the situation persists for a long time there
will be voltage collapse or Black-out situation within the
system.

3)Frequency imbalance:It is due to power generation
imbalance.If not corrected within the time limit, there will
be islanding of some part of system.

Author:arbelectbit@yahoo.com

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

what do you understand by dressing a HT/LT pole

1 Answers   Federal Polytechnic Nekede,


which frequency is to be selected for measuring earth resistivity

1 Answers   MSETCL Maharashtra State Electricity Transmission Co Ltd,


what is automatic voltage regulator and it is used?

28 Answers   ACME, TCS,


Why neutral grounding Transformer provided for generator?

1 Answers   Siemens,


WHAT SHOULD BE THE RATING OF MCCB FOR 415V,3Ph,50KVAR CAPACITOR BANK

1 Answers  


why when i start my diesel generator it takes 1 minute or less then stop, and i checked the oil sensor is ok and when the generator start i can get 220 voltage but it it is stop after 1 minute or less, how can i solve this problem?

1 Answers  


in what type of applications v can use q meter?

0 Answers  


why neutral is required in electrical system

3 Answers   Bhel,


what is the 2MVA distribution transformer efficiency

1 Answers  


what's ripple content in rectifier? how it formed?

1 Answers  


If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.

0 Answers  


What is the difference between line Distance protection and Line Earth Fault Protection?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)