What are the factors to be considered during the Synchronization?..

Answer / umesh kansara

Following factors are considered during the synchronization.
1)Frequency should be same
2)Phase angle should be same
3)Voltage level should be same
4)Impedence should be same
5)RPM should be same

Is This Answer Correct ?    7 Yes 0 No

What are the factors to be considered during the Synchronization?..

Answer / anurag sankar sengupta

the following factors are very much important in case of doing synchronization.....:
1> the incoming and running alternator should have same operating frequency.
2> the output characteristic of prime mover should be same for both the alternater.
3>they should have the capability to produce same type of output... ie.sine wave waveform.

Is This Answer Correct ?    7 Yes 1 No

What are the factors to be considered during the Synchronization?..

Answer / karthik.j(cce)

1.voltage
2.Phase sequence
3.Frequency
these three things are should be same for both the
alternator.

Is This Answer Correct ?    3 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

Can we parallel two grid with different incoming voltage. Ex.let say one grid is 132kv and another is 220kv.

2 Answers  


salam,hi, i need to know what the spesification of 300amp msb...

0 Answers  


What is the Relation b/w star delta starter , DOL starter and two speed starter. if we want to rotate a 20 kw fan in 2 speeds which type of two speed starter we have 2 use?

1 Answers   ABB,


what is MAR

1 Answers   NCC,


which motors are used in electric traction?

1 Answers  






HOW TO CALCULATE LV CABLE SIZING?

2 Answers   L&T, MRF,


extremely urgent please, why a fuse is used before voltmeter but not with a ammeter connected to a CT(current transformer),thanks in anticipation.

4 Answers   NPCIL,


Why does the power consumed is always constant even if a fan speed is altered?

5 Answers  


what is the iron loss in a 11KV/440V transformer?

2 Answers   Bhel, TVS,


WHAT IS MEANT BY SLIP , WHERE IT OCCUR

3 Answers   Suzlon,


i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT

0 Answers  


IC 741 is opampIC..moreover AND OR NOT ICs also have '74' in them.. why is that number specifically used?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)