Engineering AllOther (1379) for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?
1165If an electrical component has a positive temperature coefficient, how come such components have high power losses due to heat if current decreases when resistance increases? assuming power given by I^2*R whereby the Resistance is infinite.
1077If anyone would like to know or practice for FEWA papers contact me on mohamedrashad2@hotmail.com Just completed the supervisor exam in April 2021
1174Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.
976
Explain Power Control.
what is the value of combined earthing in general electrical circiut?
explain supply side and demand side energy management with advantages & disadvantages
what is orthogonal code of 0
How to select lightning arrester for line trap? What are the criteria?
how to compute slab reinforcements on step by step procedures??
What is meant by reset level of the relay?
How to calculate ventonite bag in pile ( pile depth 25 m dia 1m)
What is channel coding?
i need NIC written test paper or give me any idea about written exam.Plz send me at smileever8@gmail.com
If two shafts used for transfer of drive are inclined to each other, then a) Slip joint is used b) Flange coupling is used c) Universal joint is used d) None of the above
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
how could we calculate the no of outgoings from a 800 watt distribution board
What is the difference between "stress and strain”?
How to determine stage of Automatic Power factor controlling Relay(Apfcr)?