Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Chemistry Interview Questions
Questions Answers Views Company eMail

How is hardness of water caused?

1132

What is the bluish white precipitate formed after adding ammonia solution?

1098

Which is the indicator used in the determination of cao I cement solution?

993

Why is ph increases suddenly after the equivalence point?

1034

What is photoelectric colorimeter?

1035

Why is ammonia solution added while preparing edta solution?

1387

What is the unit of conductance?

1059

What is the composition of ferroin?

1098

What is edta?

1071

How is measurement of ph made?

1056

What is blank solution?

1088

What is the role of mercuric sulphate?

1077

What happens when the excess of stannous chloride is not removed

1121

What is the function of diethyl amine?

1105

What are filters? Why are they used?

1095


Un-Answered Questions { Chemistry }

For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1907


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2787


graphaite has higher melting point than fularine

2998


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1596


Explain why acetic has less conductivity than hcl?

1039


As per ICH related substances stability trend limit from initial to shelf life

3253


Which parameter require to do for analytical method equivalency?

777


What is the difference between volumetric solutions and test solutions

3193


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


Identify problem faced when mass spectroscopy is used with HPLC system ?

1861


Actinium is a radioactive element. How is its radioactivity utilized in various practical applications or fields?

624


Is benzene aromatic?

1181


What is column in chromatography?

2235


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1906


Can we consider in purity angel

1833