hello dear i have faced problem in drum level transmitter. the problem is when i engrize the meter meter shows 100% but the actual level 40 or something plz suggest me
7 9612Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
1887Name four general (not technical) criteria that would you consider important, when deciding upon a particular control valve?
1 3943Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
2209i install a DP transmitter of Faugi on drum level of boiler but i face a problem in it when i engergize the transmitter the meter shows 0 or 100% no variation in it.the distance of two points is 19.5 inches, i am in trouble please suggest me what can i do it's very urgent Please reply me as soon as possible Best regards ikraam haider
5 8062when we are using HART COMMUNICATOR why we are using 250 ohm resistance while using HART COMMUNICATOR.
7 18900what is moisture probe? What are there types? What is there working principle and how they works? guys this is one of technical question I had ask in interview. If you know its answer please let me know. The interviewers were more interested in microwave moisture probe, so if you find its any link please just forward me on my mail id.avinash1200@gmail.com Thanks in advance.
2042A pressure Tx accuracy is 0.2%. Signal o/p is 4-20ma.span is 16 Ma.how many deviate the o/p then calibration needed
1 3849Post New Instrumentation Questions
how to measure oxygen which methods are using?
How to calculate P,I&D value in PID controller ?
How earthing can be checked????
What is the Working principle of Dozing valve?
Calibration procedure for water rotameters
why is an oxygen sensor used in a boiler stack
How the warning lamp of a charging-system is activated ?
this site is owned by an nonsense
Why mmwc unit is used?
what diffrence b/w plc s7200,300,400
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
In power plant to measure vibration of a turbine we install sensors. Before install this sensor we have to set gap voltage. What is meant by gap voltage and its use?
protection relay watchdog contact operation?
WHAT IS MEANT BY PROJECT MANAGEMENT STRATEGIES IN INSTRUMENTATION?
How to Calibrate Flow Switch in field