A temperature sensor (RTD) connected via a temperature transmitter is adjusted to give an output of 4ma at 60 deg and 20 ma at 600 deg. This output (4-20ma) from the transmitter is connected to an IGBT-inverter to control a high speed (-12,000 to +12,000 RPM) DC motor. And in the inverter it is programmed as, for 4ma the motor speed will be -3,000 RPM and for 20ma the motor speed will be +10,000 RPM. The question is : If the motor speed is +5,500 (RPM), what will be the temperature? (-sign indicates that the motion is in reverse direction).
9 10439who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.
2 5192Hi,can anyone help me out with PhD programs related to Instrumentation field?I have a degree in electronic Instrumentation?
1926what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...
2 12846what is air to open and air to close control valve and difference btwn this...and how to measure milli amp by this...and what is the role of positioner and i/p converter in this..plz help me
2 45871Post New Instrumentation Questions
What is 3 selection available when configure the burnout protection for controller
what is the reset offset and control system in instrumentation
you are on site,the plant trips,you are approached by operations,what do you do?
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
what is SIL 1 2 3
why any measurement made interms of pressure is more accurate ? to be more precise most of the flow velocity is made interms of pressure and it is accurate. what is the reason behind pressure measurement being accurate ?
in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
Questions on flow meters,few questions on HART protocol,
how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?
how to measure oxygen which methods are using?
What is the purpose of bypass valve across AS valve.
If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?
what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?
How to convert milliampares into flow??