there are two candidates p and q in an election.During the campaign,40% of the voters promised to vote for P ,and rest for Q.however, on the day of election 15% of the voter went back on their promise to vote for P and instead voted for Q. 25% of the voters went back on their promise to vote for Q and instead voted for P.suppose,P lost by two votes,then what was the total no. of voters.
GATE,
1 5358there are two candidates p and q in an election.During the campaign,40% of the voters promised to vote for P ,and rest for Q.however, on the day of election 15% of the voter went back on their promise to vote for P and instead voted for Q. 25% of the voters went back on their promise to vote for Q and instead voted for P.suppose,P lost by two votes,then what was the total no. of voters.
GATE,
4 19862Explain about 4 wire instrument concept & tell about its wiring fron sensor in Field to PLC panel.Explain with an example?
IOCL,
3 13050Explain about relays.. Can we give both AC and DC to the same relay... How it is energising.. Explain its working..
IOCL,
7 14417I am a electronics and instrumentation fresher trying for a job in IT sector. what do need to prepare for the interview?
2 4622In RTU Panel we are having several Analogue & Digital Inputs /Outputs. We are recently facing some problems over Analog inputs , which are not updating properly (But Digital Input are updating normally) Can any one tell me from where the problem is creating , we have checked PLC CPU card, Analog Input card & we reconfigured ,But still the issue is there. Issue : 1. Sometimes Analog values are updating & sometimes not. 2. Analog values are not updating normally , showing some wrong Values 3. Total dead (0 value) Analog values are Level & flow measurement from the field instruments. (But in field the instruments are working normally & Displaying the values normally in local display unit) This problem we are facing in our Water Plant. If any one experienced this same problem or having any ideas related to our issue PLS send your valuable Answers/Replies...
L&T,
6 8709Post New Instrumentation Questions
How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.
Manipulation of dead wt. tester double piston type.
How the sizing of the analog signal cable is calculate?
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
Please can anybody help for control valve sizing step by step procedure?
why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?
Explain the working of an electronic level troll.
How process line mpm calculation is done?
What is the differerence between hysterisis and linearity.
Explain the working of rota meter.
How to calibrate smoke Dectector
can anyone tell me about the basic concepts to consider before to start a PLC panel wiring
how is work pressure switch& level switch?what is the principle of this?