why do we generate sinusoidal ac?can we generate some other
waveforms by alternators?
Answer Posted / sarath.k.s
Yes, It is based on the brushes used in M/c. But the
primary wave generated by m/c is always A/C
| Is This Answer Correct ? | 5 Yes | 9 No |
Post New Answer View All Answers
When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?
What is Antipumping Function & If we have C.T how we find the Ratio ?
what is the importance of earthing system on the generators big capacity and small?
Can I use distributon class/transmission class Lightning arresots for protecting the building? If not why please explain?
How to calculate that clean water supply in one Day from 150 KLD STP?
Leakage current,un balance current which relay using for high voltage transmission?
Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????
How can calculate the earthing strip of Copper/GI for rating of 30kV,discharge current 10KA Lightning arrester.
what is the series parallel connection of capacitors? and how can we use these application in three phase motors for controlling torque?
please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com
how a.c. genarator control power factor when its conected to grid supply by incrising or decresing excitation voltage.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what type of questions are asked and howmwny questions belong this catagory?
On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?
what is class of SPD and dittels of all class ?