hw to find transformer is in normal position? whether its
in charged condition or not? except humming sound?
Answer Posted / vikrant gokul labhane
1)by sensetion (vibration ) of transformer .
2)by sensing the temperature of transformer.
| Is This Answer Correct ? | 9 Yes | 0 No |
Post New Answer View All Answers
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
What is the formula to calculate the no load current of a single & three phase induction motor
What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?
Why is a plain induction motor unsuitable for wide speed control?
write a c++ code that receives an integer number and display the sum of the number and its revers integer?
where solid grounding and where grounding through ngr done and why?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
george phenomenon of synchronous machine
Yazaki india pvt ltd interview questions qurey related
why sielent pole is used only in hydro generators and not in turbo generators
We have Diesel generator of 200KW. fuel consumption is always same,even connected light load or full load. Is it right?
hai...... tis is Hemanth. jst now completed electrical engineering... i wanna to apper for ap tranco exam... plzz send me the previous q's paper link......thanx in advance.
Why back emf used for a dc motor? Highlight its significance.
different aspects of voltage stability
why we use condenser in the thermal power plant, althrough the same vapour will be again heated