What are the different ratings of the fuse units for
different distributions at your organization?
Answer Posted / srinivas0699
2,4,6,10,16,25,32,50,63,80,100,125,160,200,250,315,400,630,800
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how the testing of protection CT Testing done through Primary injection kit please describe in detail procedure...
how to select overload-relay for perticular motor 1.for D.O.L. starter 2. for Star-delta starter ????
describe the Tranformer testing procedure
how to check ac servo motor
What is speed mode?
difference bewteen reverse current and alternating current
Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors
What is the diff. between single compression and double compression gland
Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?
What is the kiosk parts, about them and their functions ? If anybody have some PDFs files or details about this plz send it on tawhidfaisal@Yahoo.com
direction of tarbine& genrator
bsnl tta exam question
I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF