Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have 12MW gas engine based power plant its running parallel
with grid. my problem is When cpp run in island mode(without
geb) that time geb transformer power factor is 0.2 lagging.
When cpp run with parallel that time power factor is 0.94 lagging
So how can i maintain power factor ofgeb transformer in island
mode 0.9 lagging?

Answer Posted / perladelsur

I had been involved in similar scenary in a 1500 MT/D chamical plant where we operated in synchonized normal operation mode condition but in case of public electrical system disturbance due to severity storn, we were about to go into the islaned mode operation.

What we did was, to install an automatic power factor control (APFC) bank to put an end at this problem so we reach o.96 PF during islaned operation.

Bye

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Z transform is use when system is not a) converges b) diverges

1687


Why is better to have a minimum ceiling voltage of 250% than 160%?

1850


Scott connection is used for A 3-phase to 2-phase conversion B to achieve higher effciency C to save copper D to reduce harmonics

2319


how define the torque in ac drive. from electrical side in the drive friquency ,voltage and current three factor is there.

2235


What happen to generator if i have unbalanced load?

2114


Why have to use copper cable for local isolator to motor ?

2112


I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.

1730


what may the reason for vector shift in a generator?

1880


How many methods use the load flow solution?

1364


when it is possible kvrah lead & fundamental kwh be equal in electonic trivector meters (3 ph)

1999


Explain the functioning of diode?

1103


why there using acb enclosure in big buildings

2117


Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.

2145


A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.

2204


could you measure current in parallel?

1118