Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why potassium dicromate use in calibration of UV VIIBLE
SPECTROCOPY ?

Answer Posted / sigilipalliramu@gmail.com

potassium dicromate having 570-620nm and uvhigest wavelength is600 so we can use that

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1715


How you develop a method in HPLC?

2609


How to set analyticl specification for combination products?

728


why octanol used to determine the partition coefficient ?

2447


How to establish relative response factor for hplc. Why it is required?

1214


is it nessesary to do solution stability for 7 days?

765


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

823


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3532


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4254


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

3206


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

913


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4055


how pda detector works over uv?

737


Why we check moisture,ash & AIA in product

1871


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2575