Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is BMS (Building Managment System)& is AHU / HVAC are
in BMS.

Answer Posted / venkatesu

BMS contains HVAC System monitoring & controls, Lighting 
system controls & Monitoring of all other facility 
equipments like elevators, escalators, D.G., U.P.S. , 
Energy meters. BMS also does integration with Fire Alarm 
systems, Access control Systems, CCTV systems & Public 
address systems for better & optimized usage of all these 
systems in any situation. It also measures & store data for 
strategic planning of optimizing of energy consumption in 
the facility. 
Now days DDC controllers communicate each other directly on 
building LAN & BMS workstation to avoid Supervisory 
controller limitations. 

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1986


Give Detail information about plc,dcs,and scada system?

1776


What is PDS and PDMS ?

2198


what is the difference between profibus and controlnet networking.

3277


In power plant to measure vibration of a turbine we install sensors. Before install this sensor we have to set gap voltage. What is meant by gap voltage and its use?

2127


What is voltage regulator?

1154


I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann

2294


what are the steps I have to deal with?

2301


State some of balance principle’ advantages?

1226


Can I calibrate the Electromagnetic Flow Meter on line and How.

2011


what is wave length were using ?

1939


what will the sending unit in the fuel gauge utilizes?

1970


Why humidity limit is 30 to 55 % for raw material storage?

4346


how to tune siemens sipart electro pneumatic positioner..plz tel me..

2197


why orfice is not used for main steam flow calculation

2184