why field winding is placed on rotor winding not on stator
winding in case of synchronous machine?
Answer Posted / dibyendu mondal
Actually 1) Armature winding have greater current than field winding.For large current in armature the greater amount of magnetic material required to produce linear magnetic curve. But rotor have lesser material than stator.
2) The heating loss on slip rings and brush contact will be increase if armature winging is om rotor.
Thank you.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the end effect of linear induction motor ??
Define step response?
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
Whether the vacuum contactor requires Short circuit protection?If No,why?
In PFI plant one stage capacitor connection is directly connected(with out megnetic contact controll). but why?
is it possible to turn on the single phase star delta on delay timer using 24 v dc ?
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
when we have to use UPF wattmeter and LPF wattmeter? what is the difference between UPF and LPF wattmeter in terms of construction?
I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?
In vapour absorption refrigeration machine fluids used are
hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com
ACCORDING TO IEC WHAT SHOULD BE THE MINIMUM HEIGHT OF G.I. STRUCTURE OF CT, PT, ISOLATOR, LA?
What happen Grid EARTH plat got cut.
What is an ideal transformer?
is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.