Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can we calibrate an actuator?

Answer Posted / rezvanian

You cant calibrate an actuator, you can just do setting.(
setting means better performance and more accurate ).
But calibration is the process of measuring the actual
performance of an instrument-under-test using lab
instruments ( or we can do this in the field ) that in
turn have significantly better performance than the
instrument-under-test. The measured performance is then
compared to published data sheet specifications. If observe
the instrument to be out-of-specification, instrument must
adjust and re-test .( for example we can do calibration for
a thermocouple or pressure transmitter )

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com

2336


Any one can help me to identified, how can we interchange the device in FF

2776


i have done DAE in Instrumentation and Process Control. i have applied for an apprentice training in chemical company after three day my interview will be conduct but i need more information about industrial process control and controller. my e mail is imran_dilsetu@yahoo.com please tell me interview question relative to instrumentation ?

2321


Explain Gas Turbine startup and shutdown sequences

4310


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2204


What is standard of DCS panel design?and what is step of DCS panel design?wiring and type of connector(screw or DB connector)

2098


how can leve transmetter calibate in feild .and also put cv and flow plz .....

2234


1.what is the power consumption of three element drum level control in sugar industries? 2.how to reduce that?

1637


How r the calculation of process line mpm.

4792


why we are using drum level control valve air to close?

2089


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2192


what is span value and zero ? and how set ?

1558


can you provide me full detail about instrumentation in ONGC??

2161


Hi, Is there any smart plant instrumentation design training institute in Bangalore?

1664


How to calibrate H2s Dectector

1613