Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how much insulation resistance 11kv & 33kv under ground
cable between earth to phase & phase to phase.

Answer Posted / shivkumar sharma

Between Earth to phase insulation resistance must be twice
of operating voltage by H.T.( 2.5 k.v./5 k.v. )megger

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What do you mean by dependent and independent voltage sources?

1042


what is draiv work

1891


a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5

1701


What is the formula to calculate the no load current of a single & three phase induction motor

2271


trasnfarmaer core make

1956


what is cathodic protection and why it use in industries?

2281


On what basis the the size of Lightning arrester for buildings are selected ?

1648


In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.

2301


what is thresold of perception

2064


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1661


How earthing/grounding done in aeroplanes and ships.

3617


What are the effects of electrical faults?

1023


can you plz send l&t aptitude questions if available its urgent plz plz plz

2110


why the rotor current becomes in steady state during high slip region? please verify with equations.

1981


What are the different power system losses and how can it be eliminated?

2047