In 3 phase induction motor 1hp current rating is 1.5 amps
constant ? is correct or not ?
Answer Posted / pradyumna chandra panda
It is not justificable that current rating of 3ph motor is culculate to 1.5 amp per hp. Reactive power is more in higher size hp motor ie. slight less current per hp. And reactive power is less in lower size hp motor ie. more current per hp. Normaly 3ph 1hp motor take 1.8 amp per phase (phase current) Simiarily current rating of 3ph 5hp is 7.5 amp, 10hp is slight less then 15 amp and 100 hp motor is approximately 140 amp.
| Is This Answer Correct ? | 5 Yes | 2 No |
Post New Answer View All Answers
how is the testing of an REF relay? what are the test REF circuit having?
What is mean by Sensitive Earth fault & what are the effects
How to dimensioning SDCCH, LAPD and CS7 signaling on GSM?
sir vizag steel ka junior trainee ka paper kitne number ka ayega
how the characterstics of control valve being done
Differentiate between magnetic field and magnetic flux?
Y phase plates are used in transmission line??? what is there need???
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
what is the meaning of the symbol << >> put in transformer drawing
Define de-sensitivity?
What does the term power factor shows?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is package substation.how many types they have
What is negative sequence over voltage element?
design of IGBT firing circuit for 11KV