how we identify between current transformer and potential
transformer without having it name plate?
Answer Posted / ram
by measuring resistance of primary coil (pt has high resistance-ct has low resistance)
| Is This Answer Correct ? | 12 Yes | 4 No |
Post New Answer View All Answers
Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel
2- What are the percentages between excitation currents in phase (R, S and T) in ∆ and Ỵ connections in excitation Current test in transformers?
What is the height of DA, DAL, DB, DC & DDE tower?
After doubling voltage from solar cells & use step down voltage transformer can we get high current output with low voltage.
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com
why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?
How many devices can be connected in one zone of FACP
I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.
How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?
What is load boxes ?
1.Z transform always lies around ? a) origin b) pole c) zero d) z=1. Multiples Mcqs which is bother me can’t find answers on internet. Some help required with little explanation . Note: this is not homework or related to any test. Thanks
derive DC RMS value for half wave rectifier?