Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the capacity of power plant is given in MW though the
generators are rated in MVA?

Answer Posted / lalit

if we talk about the generator then we have to classify the
active power as well as reactive power i.e. V*I because the
reactive power is also used in generator for the excitation
purpose( for flux production). hence its rated as MVA in
other hand, for power transmission only active power is used
i.e. VICos theeta. hence its rated as Mw.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does PLC work for sychronising of Two or more DG sets?

2071


LET ME NOW MORE ABOUT icu and ics for circuit breaker. how we calculate the rating of circuit breaker and i c u and ics values

2868


What is an 86-P or an 86-A trip

2072


what are the disadvantages in GIS over AIS

2415


What is a surge supressor why its is used in synchronous generators

2013


If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.

6114


State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp

2076


Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?

1424


why output is out of phase in case of common emitter?

2134


while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2851


What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating

1532


What cmos is and its benefits?

1206


What is the difference between circuit breaker and isolator

1244


how ups works ? various parts of ups and working principle

1982


What is center gravity load in substation?

2416