Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to calculate KW what is the formula for KW.

Answer Posted / p l narayana

KW is an electrical specification that which intends the
amount of energy required to do a job
The given example will give an idea to calculate KW
10KG object is to move one meter distance in one
section then required kw is =weight*g*d/(t*1000) KW in
mechanical terms
Now in electrical terms
KW=V*I*PF
= 3^0.5*V*I*PF
WHERE V=Phase voltage
I=Phase current
PF=Power factor

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

2273


Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??

1871


which protection used in power plant?

1958


Explain cos(theta) and Sin(theta)

2107


Please brief me about number of pole in alternator.In single phase alternator coils are connected in star or series. How to calculate frequency for the same.

1910


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2744


Define unilateral circuit?

1243


is the value of inductance depends upon the evalue of thitha in doubly excited machine?

1880


what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable

1978


what do you mean by type zero control sytem ?Give an practical example of type zero contol sytem?

1968


Is any generator is developed which is operated with out diesal or other expensive source?

2108


define as synchronous generator

2144


where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz

2143


DEAR SIR/MADAM,CLEARLY EXPLAIN ABOUT CRAWLING AND COGGING EFFECTS IN INDUCTION MOTOR.

1901


If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1883