if storage contain 500 disks in this one disk is failed,we
placed new disk in failed disk place,how can we find out
exact path of the newly installed disk when we execute
format command?
Answer Posted / saravanan
iostat -En for solaris it will show all disk include failed
disk... after find out failed disk..
this is SVM
(1) metadb -i all disk ... after findout failed disk..
(2) metadb -d remove disk
(3) metadb -i verify the disk whether disk removed..
(4) phycsically insert new disk
(5) devfsadm to run... it will bring disk into OS level after
(6) cfgadm to run it will bring disk under SVM
(7) metadb -a -c ctds create state data base
(8) metadb -e <olddiskname> <newdisklname>
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is cachefs?
how can u give space garentee for volume in netapp storage
Hi, I need information regarding LDOMS.Like What is LDOMS ,Creation of LDOMS, errors on LDOMS, troubleshooting LDOMS...etc.... pls post the info. Regards, Naresh
what is mean by netfmd in sun cluster what is the use of netfmd and what is the relation between ccd and netfmd?
What is the zone in DNS?
In a two node cluster i have typed #hastart command in one node.The cluster is starting in second node also,what is going in background?
Local zone in shutting down state.how to bring state of zone to installed?
How to create a gateway?
What is the use of Sam utility in solaris
when i am starting solaris10 with 'fail safe mode' on intel machine it is asking "#starting shell".what is it and how to solve this problem?
How do u know that,what patch can be applicable on the system?
hi to all,, i need few real time issues please provide me,, if you have any,,,