We use ungrounded DC system (220V/110V) for control and
protection system in substations etc. Suppose we have long
2 core DC cables running from our DCDB in control room to
the load (length of around 2 to 3 km). Do we need to
protect these long DC cables from earth leakages or not? If
yes how?
Answer Posted / sanjay choubey aditya electron
You can use online Insulation Monitor Bender Germany make
products for above requirement you can also see website for
more details: www.bender.org many Steel Plant, Substation
are using Bender products same applicaton.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
A cylindrical wire is compressed in length by 10%. The percentage decrease in the resistance will be?????
what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
What is corkscrew rule?
What is mathematical model of a control system?
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
Difference between transition and diffusion capacitance
draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it
Do any one know exacatly when the results for NHPC held on 8th march 09 for engineering trainees will be released ?. if so please post it, i'm eager to know it.
Which level of the Transformer oil got dielectric strengh? And why?
please describe the Transformer setting, Motor setting, I/C setting, Tie setting
why are u join ntpc
What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw
Capacitor is load free component but why ampere meter shows current when capacitor bank breaker close?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.