Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Which phase is prefered for connecting 1phase vt used for
synchronism in an OHL? why?

Answer Posted / k.prakashchandra

Usually R phase is selected.But any phase will do,as phase
sequence is important.The generator does not have fixed
phases.Any phase which when synchronized with the fixed
phase of the system ,becomes that phase.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

2203


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2308


can indirect loading be called as phantom loading?

2131


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1960


i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors

1800


what is basic difference betmeen normal & flame proof motor??

2102


What should be current in the Primary and secondary side of 1000KVA (11KV Supply)Transformer.?

1007


how we will deside the high voltage value

1914


why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)

2411


am commissioning the trafo without connecting the neutral therefore unbalance will occur what is the alternative solution for this?

1783


Why are cables rated for 40 KA for 0.25 Sec fault current rating?

1883


What kind of preventive maintenance are there for transformer?

2206


How to know about the rating(voltage and other) of induction motor if its name plate is missing at the manufacturing site.

3328


will 1050kva DG set withstand for back charge of 16MVA transformer

1800


how to enter inverter parameter? without manaual?

1976