1.Why use in ups in software's,reason,and pls explain.
2.what is the isolation transformer and main use it's
functioning and partes.
Answer Posted / ramendra shukla
The UPS is a device which provide us the continuous power
without any breaking in normal supply.Due to requirement of
continuous supply for critical load UPSes are get used in
IT companies as well as for Non IT companies.
Untruptted Power Supply (UPS )-have mainly five parts-
Rectifier,Battery Bank,Inverter,Switching & controlling
devices.Their working is based on logic controll.
At the presence of normal electric supply the load flows
from Rectifier-Inverter-Switch but when AC supply in not
presented at all then Battery units come into picture.By
the working principal or inverter i.e. from DC -AC it
feeded AC supply to the load after Ac filterisation.
When there are any problem in Rectifier ,inverter, Battery
etc. unit then supply goes through bypass.
Isolating transformer is a type of X-mer which isolate the
a circuit to its design.and also the No. of primary
&Secondary tern of Iso. X-mer are same are equal that
facilitates to isolates and reduce the fluctuation and also
create Neutral supply for load.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What are the disadvantages of autotransformer?
how does the terminal voltage of transmission lines increase when a capacitor is connected???? This happens not only in transmission lines but also in all circuits. How??? When a capacitor is connected in a transmission line, capacitor also takes energy from the same supply. But how is it able to increase the terminal voltage??? Practically What sequence of events happen during increase in voltage???
either water sensor or flow meter,how we observe the water level, f any other equipment are in market ?
Write down the name of 2 lady Bir Pratin of Bangladesh
what r the safety measures in UPS ? explain all?
what is the pulse and audio frequency transformer? what is different between induction regulators and tap changing transformer?
How we can recongnise the phase displacement of transformer connection between primary & scondary...plzzz explain it with example.........
Why should be the frequency 50 hz 60hz only why not others like 45, 95 56 or anything , why should we maintain the frequency constant if so why it is only 50 hz 60hz?
for a 400kv t/m line with 10 ampere current will corona occur?
What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?
im electrical engineer, could any one help me for FEWA exam questions please ?
State thevenintheorem?
why transmission is only 3 phase and not 2 or 4 or poly phases
how we calculate the dick for a pole?
What is meant by analogous system?