Why we choose 400kv,220kv,132kv,66kv,33kv transmission
voltages for transmitting power. Why not other voltage
levels.
Answer Posted / binay kumar jena
As generation level is generally 11kv or multiple of 11 and
the insulators are designed for 11kv level or multiple of
11 thats why transmission is also multiple of 11,
| Is This Answer Correct ? | 2 Yes | 9 No |
Post New Answer View All Answers
1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?
i have interview in Pepsi company what type of question will ask please send the question and answeer
with 3 phase board on a 63 amp rcd is it ok to have 6 electrical showers 2 on each phase and what problems could happen
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
1) What are your personal strength? 2) What are your personal areas of improvement? 3) What are your expectations from from a particular job? 4) what are your carrier objectives?
what is a bus riser in power system and why it is used
How to define Kirchhoff current law and voltage law along with simply examples.
What is gain margin?
why we have and use 3 phase not 2 or 4 or other in power system?
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?
what is PWM in IGBT and how it works for drive.?
How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.
What is order of the system?