Answer Posted / hari
1)air cored reactor soft starters(hormonic effect free)
2)Iron core reactor soft starters(hormonic effect will be
there)
2)flux compensating magnetic amplifier starters(FCMA)
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
in ACB breaker requireding 3200Amps. buscoupler getting OFF mode and again it reset and getting normal position give me a required answer?
What are the types of windings according to the construction?
hi can anyone pls tell me the eee interview core questions asked in l&t
How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.
How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?
why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?
i am going to attaned the engineer (disign)iterview at HAL please give me duid line
Explain the terms real power, apparent power and reactive power for ac circuits and also the units used.
What is the function of Governor in Hydro Power Station? What is the Function of Lightning Arrestor Voltage Transformer (LAVT)?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How to decide DO set rating of Transformer?
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
what is a pulse transformer? how rise time of pulse changes when ever the voltage changes?
what is Fault level? why it is calculated? how will u decide same for our plant?
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend