what do you mean by leading power factor & lagging power
factor
Answer Posted / er. ankush miglani 9718151073
P.F.=COS#= TRUE POWER\APPARENT POWER
FOR INDUCTIVE LOAD INDUCTOR IS USED WHICH OPPOSES THE
CHANGE IN CURRENT IN THE CIRCUIT AND STORES THE ENERGY IN
THE FORM OF CURRENT AND LEAVES IT LATER. HENCE THE CURRENT
CURRENT WAVEFORM LAGS THE VOLTAGE WAVEFORM, AND THE POWER
FACTOR IS CALLED LAGGING./
FOR CAPACITIVE LOAD CAPACITOR IS USED WHICH OPPOSES THE
CHANGE IN VOLTAGE AND STORES THE ENERGY IN THE FORM OF
VOLTAGE AND LEAVES IT LATER. HENCE THE VOLTAGE WAVEFORM
LAGS THE CURRENT WAVEFORM, AND THE POWER FACTOR IS CALLED
LAGGING BUT THE CURRENT LEADS THE VOLTAGE AND HENCE THE
P.F. IS CALLED LEADING P.F.
| Is This Answer Correct ? | 45 Yes | 10 No |
Post New Answer View All Answers
how test transfomer(3 phase75kva) by megger
what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth
All tape of electrical questions Answers tape of motor transformer e.o.t crane
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
What are the properties of a resistor?
what is ramping rate of generator
Difference between rating factor of cable and derating factor of cable?
plz send me Bhel, Mahagenco, sbi previous exam paper for electrical engineer on my email-id kambali_smita@yahoo.co.in
When semiconductor fuse does save thyristor in each cycle of conduction? Why under voltage setting keep less in SPRS and more in DC drive?
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??
1.What is captive power plant? 2.What is national grid?Give brief idea.
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
how give earthing conection to household equipment?
why is the power generator connected as star earthed or star earthed through reactance and what its features ?