why contactor not provided between output of VFD and motor?

Answer Posted / jayaseelan

This will cause unnecessary wear on the contactor and
there will always be a slight delay while the inverter
initialises.ie.if contactor placed in between vfd and motor
response time of contactor gettting on is slow compare to
vfd response speed so return current wii affect the
electronic bords.thats y contactors not not used in output
of vfd.

Is This Answer Correct ?    6 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why are the laminations insulated from each other?

757


In dc ckt. 24v or 110v, which one is more efficient and why?

1873


Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?

1626


1 “earthing” for bonding of equipment and circuits to common plant earth electrode potential, 2 “protective earthing (PE)” when this bonding is required for personal safety provisions 3 “grounding” for interference suppressing bonding of screens, sys-tems with ground level 4. low-impedance earthing ? 5.primary earthing system and secondary earthing system what is that? 6.earthing electrode or mesh net earthing electrode ? very confusing , simple but very informative help required ? i will be very very thankful to you guys.

1695


Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????

1481






What are the relays in ACB and VCB

1778


1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?

1635


how to calculate slip ring induction motor stator and rotor currents??

1888


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

1681


Why arc quenching is used in Diode ?

1659


What is difference between insulating medium and fault current interruption medium in a switching device.

1236


Brief working principle of stabilizer,application & safety precautions

5260


how to calculate fuse rating for a motor

5048


I am an American living in Vietnam and I have recently gotten a refrigerator from Japan and it is rated for 100 vac, but the power here is 220 so I bought a voltage stabilizer it has a 1 kva output rating. Can you please tell me what the amperage is? I'm confused and without a working fridge.

1359


why we can stote dc? why we cant store ac?

1737