what is the effect of earthquake on rcc columns &
foundations?

Answers were Sorted based on User's Feedback



what is the effect of earthquake on rcc columns & foundations?..

Answer / prashanth

Foundations-Depends upon the rchter of the earthquake
usually it may settle,cracks.

RCC column-if foundation settle then column will develop
cracks

Is This Answer Correct ?    7 Yes 0 No

what is the effect of earthquake on rcc columns & foundations?..

Answer / kohinur

Effect of earth quake mainly depend the structure's share factor and damage may developed through the weaker section in share. It may cause big crack development and failure to withstand stable.

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Civil Engineering Interview Questions

Slow setting admixture is used in mass concrete because of – –

4 Answers   Reliance,


how to calculate 162/D2 FOR TMT

3 Answers   McNally,


What is full form of r.c.c?

1 Answers  


why crakes are developped in opening corners

3 Answers  


How to estabilish reinforcement Steel rolling margin for a building projects ?

0 Answers  






what is mean by bPo in construction? pls tell me

1 Answers   Sangini, SRM, SV,


Gave a cantilever beam with 3 legs.Told to draw the bending moment diagrams, axial force diagrams and shear force diagrams.From BMD he asked to show how the reinforcement will be provided on the tension side.

0 Answers   L&T,


why we use 19x9x9and 20x10x10 but not other

0 Answers  


what is conventional shuttering rate per square feet of built up area? what is Mivan shuttering rate per square feet of built up area? what is coupler shuttering rate per square feet of built up area?

0 Answers  


if we know load bearing capacity of the soil and building load falling in each footing, then how to choose the type of foundation??? and if it is shallow foundation then which type of shallow foundation should be choosen i.e either strip or isolated or raft or combined or cantilever footing???????

0 Answers  


1 building project (work in progress) and following are sum detail about his project 1) Using local rebar grade 415 2) Total built up area- 60000 sq.ft 3) Floors to be constructed – 21 storey 4) Estimated requirement of Steel per sq. foot – 7KG/sq.ft 5) Concrete grade – M35 6) Rebars mainly required (sizes)- 16,20,25,32 & (8 mm for stirrups) Wanted to ask u if this person uses 500D…what are the benefits he will be getting? Whether his per Sq. foot consumption can b reduce? If yes den around how much?

1 Answers  


How to calculate the dia of reinforcement when required (as per drawing) dia of reinforcement steel not available at site?

3 Answers   MNC, N J Devani Builders, Simplex,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)