I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are
1) Is it safe to use this switch with the motor I have
2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
No Answer is Posted For this Question
Be the First to Post Answer
what is the main parts of DG? how it is working?
Define reserve-generating capacity?
How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?
Questions :- HR- Q.1 about yourself & family background ? Q.2 Why u choose Power sector as ur carrier starting not any other sector ?? Q. 3 What think abt NTPC ? Techincal Questions:- Q.1 about Vocational Training……What u did , see the main equipments….etc Q.2 Why a transformer Noise during its running condition ? Q.3 about transformer oil material & Test name for the measurement of its dielectric strength & wht will u do if its dielectric strength goes low ? ……..some discussion type ? Q.4 What is relation between transmission lines & Communication lines ? Q.5 Which Machine u will prefer to use at a place where flammable gases are coming out & why ? Q.6 how fault in an electric system is detected & hw protection of equipments is done ? Q.7 Why we didn’t feel electric shock in an electric train ?? Q.8 Anything u want to ask from us ??
44 Answers Akona Engineering, Bhel, BSES, Cranex, DRDO, JCB, NTPC,
Why two nos. un-tensioned wires are placed inside the PSC poles used by powergrid in RGGVY works.
How to configure the drives in PLC, through Profibus commnication. And to how to address it?
WANTCONTACT NUMBER & EMAIL/ WEBSITE TO CONTACT THE SECRETARY,MADHYA PRADESH LICENSING BOARD(ELECTRICAL),K- BLOCK,3RD FLOOR,SATPOODA BHAWAN,BHOPAL
A 11000/415V distribution transformer is fed 415V upon it's LT side,Do I get 11000V upon it's Primary side ?
what is the maximum current carrying capacity of a 95 sqmm cupper under ground cable laid partialy in land and partialy in ground?
what are the basic insulation levels & what its Unit
Dry type transformers
Which of the following loss varies with the load A hystresis loss B eddy current loss C copper loss D core loss