What is the lapping length for 32mm steel rod as per BS standards?..

Answer / swapnil vijay vedpathak

Lapping of 32mm steel for column = 45×32=1440mm. Lapping is allowed to 32mm steel .but binding is not allowed . They requires welding.

Is This Answer Correct ?    5 Yes 3 No

What is the lapping length for 32mm steel rod as per BS standards?..

Answer / sjtbehera

answer is if you bgo thumbrule 50x32=1600mm mm =1.6mt i m20 conc
in m25 conc - 1312 mm = 1.312mt m25 conc.

Is This Answer Correct ?    8 Yes 7 No

What is the lapping length for 32mm steel rod as per BS standards?..

Answer / naresh

IN M25 Concrete - 32 MM dia Steel bar Lap should be LD*32 Dia i.e. 32*49=1568MM

Is This Answer Correct ?    3 Yes 3 No

What is the lapping length for 32mm steel rod as per BS standards?..

Answer / akash singh

lapping is not allowed for 32 mm steel rod !

Is This Answer Correct ?    8 Yes 11 No

Post New Answer

More Civil Engineering Interview Questions

as per is code, what is the minimum content of opc and ppc cement for rcc structure

0 Answers  


What is the mixing of D.P.C?

3 Answers  


state the difference between direct and indirect cold water supply scheme

1 Answers  


Which is default or standard size of tiles used in dado bathroom

9 Answers   Orbit Corporation,


7500 liters capacity of water tank find the inner Length L = ? Breadth B = ? Depth D = ? in feet

3 Answers  






how to do soil testing briefly with details

3 Answers   Deepak Enterprises,


1- what is steel rebar cover? 2- what is a rebar stirrup?

1 Answers  


pls give the grads of concrete and the ratios to the same

2 Answers  


How much binding wire required in 1 MT Reinforcement? How much Nails Required in 1 Sqmtr Area work progressed

1 Answers   Adhunik,


what is diffence in grade 43 & 53 of cement?

4 Answers   KFC, L&T, NICE, Puravankara,


castigliano's theorems are based on

6 Answers   Essar,


IN CIVIL ENGINEERING DESIGN WHY WE ARE USING LIMIT STATE METHOD IS BEST? I THINK WORKING STRESS METHOD IS BEST? EX; FOR COLOUMN DESIGN IN LIMIT STATE METHOD AST IS;1913SQ.MM SAME TIME WORKING STRESS METHOD IS ;2213. SO I THINK WORKING STRESS METHOD IS VERY STRONG COMPARE THEN LIMIT STATE METHOD? MY OPENING IS CORRECT OR NOT? PLS TO EXPLAIN SIRS

12 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)