Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why mostly conductor made by 7 nos wire?

Answers were Sorted based on User's Feedback



Why mostly conductor made by 7 nos wire?..

Answer / suman p.d dhakal

Easy to band and its gives more fexible.

Is This Answer Correct ?    3 Yes 0 No

Why mostly conductor made by 7 nos wire?..

Answer / kj

A centre strand and 6 strands fit neatly around this
strand. Next is 19 strands where a layer of 12 starnds on
top again. And so on as the cable gets thicker.
The cable is then flexible.

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

How we can calculate the Amps for the cable Ex:- For 1sqmm wire how many amps we can draw (calculation)

0 Answers   TATA,


how to find diesel consumption of 600kva DG per hours????

1 Answers  


how to convert 1 phase power to 3phase power by using induction motor. . . .

1 Answers   BK Anand,


How the flights will be fly be fly without ground connection under raining with thunder lighting?

1 Answers  


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

0 Answers   Indeco,


What is the function of induction motor when low voltage is apply.

6 Answers  


How to calculate or testing the KW in generator

1 Answers  


We have a 62.5 KVA DG with Leyland engine and kirloskar slipring alternator. We have earthed the neutral, and another earthing for the dg body. is it necessary to isolate the dg foundation with rubber pads?

1 Answers  


For 280kw power. Which cable I can usr

3 Answers   Clean World, TCS,


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

0 Answers  


Active power= VI COS FI But incase of leading power factor ( more than unity), may we use other formula ? because the cos fi (value of cos thita) should not be grater than one.

2 Answers  


why the projects getting loss?

0 Answers   SBPL,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)