what is the Reynolds number
Answers were Sorted based on User's Feedback
Answer / thambirajan
REYNOLDS NUMBER=INERTIA FORCE PER VISCOUS FORCE
REYNOLD NUMBER IS LESS THAN 2000 THE FLOW IS LAMINAR
MORE THAN 2800 THE FLOW IS TURBULAND
BETWEEN 2000 AND 2800 THE FLOW IS NEITHAR LAMINAR NOR TURBULAND
| Is This Answer Correct ? | 11 Yes | 2 No |
Answer / mustansir pancha
Reynold's number is the ratio of (density * velocity *
length) / (dynamic viscosity u)
It helps determine whether the flow is laminar or turbulent.
If reynolds number is more than 3000, then the flow is
turbulent in case of water.
It has no unit.
| Is This Answer Correct ? | 7 Yes | 1 No |
Answer / vignesh.p
Reynolds number is used to
find out the type of flow
ie.whether it is streamline or
turbulent...it has no unit
| Is This Answer Correct ? | 5 Yes | 1 No |
Answer / pkg
reynold number is dimension less number that is equal to ratio of inertia force to viscous force. Re tells about flow type tubulent(>4000) or laminar (<2000).
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / kundil phukan
It is the ratio of inertia force to the viscous force.According to reynold the transission from laminar to turbulent flow in a pipe depends on velocity,pipe diameter and kinematic viscosity of the fluid.At critical reynolds no of 2000 flow starts changing from laminar to turbulent
| Is This Answer Correct ? | 0 Yes | 0 No |
Define Overall Heat transfer coefficient.
what is the use of vanadium (non metal) ?
What is a clock maker called?
Explain the difference between grey iron and white iron. What is mottled iron ?
in power plant which pump is used for feeding the water a) centrifugal pump or b) reciprocating pump. and why?
What is control volume system?
what is BOOSTER pump which is used in power plant?
What is meant by reflectivity?
What is pitting ? How it is caused ?
When a 30KW/3 ph pump runs one hour continously, what will be the heat dissipated? how can i find this, any general equation?
Is it possible to make common ducting for Induced draft boiler with Forced Draft Boiler? Induced Draft Boiler is having Agrowaste type and Forced Draft Boiler is of Oil Firing type.
0 Answers Janardan Metal Industries,
What are the causes of emergency stop in a steam engine?
0 Answers ABC Inc, RRB, Siemens,
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)