what s available NPSH and required NPSH? which is given by
manufacturer and which is not? what is the role of customer
in choosing NPSH?
Answer / rudrappa
NPSH Required (NPSHR): The minimum pressure required at
the suction port of the pump to keep the pump from cavitating.
NPSHA is a function of your system and must be calculated,
whereas NPSHR is a function of the pump and must be provided
by the pump manufacturer. NPSHA MUST be greater than NPSHR
for the pump system to operate without cavitating. Put
another way, you must have more suction side pressure
available than the pump requires.
| Is This Answer Correct ? | 20 Yes | 1 No |
What phenomenon becomes when air mixed with refrigerant?
plese send me the rrb model questions for JE mechanical
What is isotropic material ?
As compression ratio increases, thermal n increases. How is thermal n affected by weak and rich mixture strength ?
how many types of heat transfer?
What is meant by lmtd?
what should do to reduce the breakdown of fire water pump?
a three phase squirrel cage induction motor runs slow? list all possible reasons for such fault.
What causes diesel engine trouble when using heavy oil?
What is the Full form of AIF in Compressors ?
Low water in boiler drum is unsafe because it may result in overheating of water tubes in furnace. Why it is unsafe to have high water condition in boiler drum ?
How you are going to remove corruption?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)