Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

Please do not join if u got offer in oncotherapies ltd (STRIDESARCOLAB)especially Mr.Mahesh Bhatt team because job is not secure his team and doesn't have confidence on him becareful this offer?

Strides Arcolab,

1 4835

In partical size by malven,which parameter is generlly change for development of dry and wet method.

1 3294

As per ICH related substances stability trend limit from initial to shelf life

Medley Pharmaceuticals, Micro Labs,

3193

what is the difference between EP and BP

Novartis, Vimta Labs,

2 20970

which detector is used in IR

Hetero,

3 15004

why hexadecane is used in calibration of FID IN GC THERE IS NO REMAINING SOLVENTS

DRL, Hetero, MSN,

1 8094

WHY POTASSIUM HYDROGEN PTHALATE IS USED FOR PERCHLORIC ACID? What is difference btw UV detector & RID detector? what is dissolution? What is unit of KF? what is the significant of pH in HPlc?

1 9892

what is dissolution What is unit of KF? what is the significant of pH in HPlc? WHY POTASSIUM HYDROGEN PTHALATE IS USED FOR PERCHLORIC ACID? What is difference btw UV detector & RID detector?

1 8036

I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3495

Hplc detect how much ppm solutions i want range

4 11319

If we change lenght of ph eletrode wire then it will affect on ph ?

2 7997

In kf constant term 16 what it is explain ?

2 8481

Why dissolution apparatus having 8 jars ?

5 16808

What is the unit of Colour?

IPCA,

4 10976

who is the father of HPLC?

Cipla, IPCA,

6 21167


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

Which parameters require to do in tech transfer?

687


Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2295


what are risk assement in the analytical qbd?

692


why digestion require in icpms?

733


Why six unit used for precision?

1278


which are the diffrent batches in the pharmaceuticals?

775


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1926


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1648


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1748


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2543


in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?

718


if your product is soluble in 0.1n hcl and water then which you choose as media from these 2 media?

636


how you determine moist.of NaOH sol or NaOH flacks

2183


why cone formation during dissolution?

736


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3495