The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?
2327If a normal magnetic type flow transmitter that can measure flow, temperature and show this parameters on field, is it possible by any means to get this (flow and temperature) parameters info. On dcs? And if yes then with HART, FO communication or any other communication system?
1 2950If a flow transmitter (magnetic type FT) that can measure flow and temperature, then why in some industries people use flow transmitter and temperature transmitter in the same line 1 after another? Even after 1 single flow FT is capable of measuring flow as well as temperature.
1 4756I have installed a RTD whose length is 2250mm(RTD stem length), but it's upper 200 -250mm is out of the reactor, and this upper 200mm stem is surrounded by atmospheric temp. And the lower portion i.e. 2000mm is in contact with the measuring fluid, then does the final measuring temp. Gonna change as the upper 200mm RTD stem is out of reactor?
1 2775How does a single acting, spring return ball valve actually work? Does it require continuous air supply?
2190In a ball valve which require 24v dc supply to operate, whose solenoid valve doesn't have any + or - indication, how can we make wiring connectionto solenoid valve?
1 4366What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?
3226Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?
2210Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions?
2224Why is the length of cable layyed from RTD to temp. Transmitter should be minimum? Why does heating effect takes place in their?
1 6355Why do we use triad cable for RTD to Temp.transmitter connection? Why we don't use 3 core cable?
1 15110What are continuances of connecting earthing and shield of branch cables (instrument to Junction box), at the same earthing pot provided on JB? Is it ok, or may produce some problem?
2531Post New Process Control Technologies Interview Questions
Explain what is Visual basic?
What are comments and how do you insert it in a C program?
Is tomcat a web server?
How to Send a message to all controls on a form 16-JUL-98?
Explain voip?
Which licensing authority is responsible for wordpress?
How do you find out computer specs?
Evaluation?
How can I see all command prompts?
How does your preferred work style work with the ideal test-manager role that you just described? What is different between the way you work and the role you described?
Explain enhancements
The launch action shown is not accessible to a newly created process p1. What is the problem?
what are the roles of an xi architect?
Which messaging is generally used in cases where a message is published by a producer and consumed by multiple subscribers?
How to get the value of selected option in jquery?